ORIFICE PLATE DESIGN AND CFD ANALYSIS AT DIFFERENT VELOCITY RATIOS
Authors:
C Ramakrishna, Khairunnesa Begum, G. Ranitha
Page No: 57-62
Abstract:
Flow measurement is measurement of the quantity of the fluid that passes through the pipe, duct or an open channel. Flow may be measured by measuring the velocity of fluid over a known area. Differential pressure measuring devices such as orifice plates and nozzles are extensively applied in several industries to estimate the mass flow rate running through a channel by correlating the measured pressure loss. In this paper, an orifice plates with different geometry were designed and compared on the basis of their coefficient of discharge. This was done with the help of simulations done with k-ε and model on CFD as a solver. Simulations were carried out on a single hole, perforated (6 holes, 8 holes) at different Reynolds numbers (6000, 8000 and 10000).In this thesis the CFD analyses to determine the pressure drop turbulence intensity, and velocity. 3D modeled in parametric software CATIA and analysis done in ANSYS.
Description:
.
Volume & Issue
Volume-12,ISSUE-3
Keywords
.