PV BASED SHUNT ACTIVE HARMONIC FILTER FOR ELMINATION OF HARAMONICS
Authors:
Mr.B.Sreenivasa Raju, L.V.N.Sai Charan Abbaraju, MD.Munzeera, K.Revanth, P.Yuva Kishore
Page No: 485-492
Abstract:
This Paper explores about the analysis of the two stage “SOLAR PV” System using “Shunt Active Harmonic Filter”. Recently, during the industrial revolution, due to innumerous amount of erratic loads,the current harmonic problem has had an impact on the distributed power system. The SAHF system offers load compensation, power factor improvement, and harmonic mitigation. The three-legged VSC and DC power taken from the PV module are used to build the SAHF system. The first stage of this double-stage system is a DC-DC step-up converter that uses the “MPPT” algorithm. The Perturb and observe algorithm is used to extract the most power possible. In the second stage, hysteresis and the PI controller are used to determine the reference current extraction driven by a current controller and PWM.
Description:
SAHF, MPPT, P&O, PWM-VSI, VSC
Volume & Issue
Volume-12,Issue-4
Keywords
.